Home ] Up ] Customers ] Contact Us ] Home ]

 

HIDStarter-600-10.jpg (13232 bytes)

 

Click on image for larger picture

 

HID Starter Tester

 

High Intensity Discharge Lighting Starters

 

         production line full function testing

         nine internal ballasts

         external ballast hookup

         120 / 240 VAC electronic power source

         automatic test sequence - approximately 7 seconds

o        ground continuity

o        hipot

o        validate occurrence of and count pulses in pos / neg half cycle

o        validate occurrence of and count pulses in acceptable position window

o        validate and count pulses above voltage threshold in pos / neg half cycle

o        validate and count pulses above voltage threshold in acceptable position window

o        measure width of up to three acceptable voltage and position pulses

o        repeat for selectable number of positive and negative half cycles

o        pass / fail decision made on percent of total cycles meeting test criteria

         offline Windows based recipe editor to generate test parameters

         easy transfer of test recipes from editor to tester

         embedded IBM PC compatible computer control

         front panel keyboard and 4 x 20 alphanumeric display

         data logging to floppy disk

         optional data logging to high speed network

  •   full menu guided operation with extensive utilities